Selma Celikovic, Johannes Poms, Johannes Khinast, Martin Horn, Jakob Rehrl
https://doi.org/10.1016/j.ijpharm.2023.123038
Methods for the real-time monitoring and control-oriented modeling of critical quality attributes (CQAs), specifically particle size distribution (PSD) and active pharmaceutical ingredient (API) content, in wet granules produced by the twin-screw wet granulator (TSG) of the ConsiGmaTM-25 manufacturing line were developed. The granulation process was modeled using the Local Linear Model Tree (LoLiMoT) algorithm. The integration of Raman spectroscopy with chemometric modeling enabled real-time assessment of API and liquid content, while the spatial filter velocimetry-based PAT probe facilitated continuous granule size monitoring and supported systematic and efficient model development.